Process Analyzers

  • Filter

Toroidal type teflon detector with excellent corrosion/heat/pressure resistance  Accurate results for high conductivity corrosive solutions (such as strong acid/alkali) Types of detectors available: flow-through, immersion, pipeline insertion, etc. Meas. range Minimum: 0 - 2 mS/cm Maximum: 0 - 2000 mS/cm

Compact toroidal, heat resistant PVC type or Teflon detector with excellent corrosion resistance are available Accurate results for high conductivity corrosive solutions (such as strong acid/alkali)  Types of detectors available: flow-through, immersion, pipeline insertion, drop-in, etc.  Meas. range Minimum : 0 - 500 μS/cm Maximum: 0 - 2000 mS/cm

Panel type DO analyzer in a compact DIN 96 size One-touch calibration and various self-diagnostic functions 2-point contacts signal, 4 - 20mA output (RS-232 optional)  Power supply: 90 - 264VAC, 50/60Hz Meas. range Minimum : 0 - 1 mg/L Maximum: 0 - 50 mg/L

Immersion/Drop-In Type DO Holder OC-711 / OC-950 Lightweight PVC holder; length of immersion type holder: 0.3 - 3.5 m, length of stainless steel protection pipe for drop-in type holder: 2 - 6 m Electrode: polarograph type 7533L (for standard use) or 7536L (for human waste)

Detector with Water Jet Cleaner JOC-711C / JOC-950C Cleaning electrode contamination by jetting water or air onto the electrode Immersion type (JOC-711C) and drop-in type (JOC-950C) Electrode: polarograph type 7533L (for standard use) or 7536L (for human waste)

Industrial Low-Concentration DO Transmitter ODM-100A (2-wire) / ODM-110A (4-wire) Easy-to-use low-concentration DO analyzer for field installation in a compact and rigid aluminum case Simplified calibration procedure; auto detection of electrode deterioration Alterable output range Automated self-diagnosis of fault (burn-out output) Meas. range Minimum: 0 - 20 μg/L Maximum: 0 - 2000 μg/L

Low-Concentration DO Transmitter OBM-300 (4-wire) Multi-functional low-concentration DO analyzer for field installation in a compact diecast aluminum case 3 ranges (automatically switched), 2-point regulated output Alterable output range One-touch calibration and various self-diagnostic functions Meas. range Minimum : 0 - 20 μg/L Maximum: 0 - 999.9 μg/L

Panel Type Low-Concentration DO Transmitter OBM-100H Panel type low-concentration DO analyzer in a compact DIN 96 size 2-point regulated, 4 - 20mA, RS-232 output One-touch calibration and various self-diagnostic functions Power supply: 90~264VAC, 50/60Hz Meas. range Minimum : 0 - 20 μg/L Maximum: 0 - 1000 μg/L