DKK-TOA

  • Filter

Electromagnetic Concentration Transmitter MDM-137A (2-wire) Electromagnetic concentration analyzer for field installation in a compact and rigid aluminum enclosure   Conductivity of NaCl, HCl, H2SO4, etc. are measured and converted to concentration (%)data automatically Assignable measurement range Examples of measurement ranges NaCl: 0 - 10% HCl: 30 - 40% H2SO4: 93 - 99.5% NaOH: 0 - 15%

Automated Total Nitrogen Analyzer TNC-250 Reagentless thermal decomposition and chemical luminescence methods adopted Suitable for measuring seawater samples Capable of measuring samples including SS Front-panel operation enables easy maintenance Meas. range 0 - 20/50/100/200/500/1000 mg N/L

US EPA Approval Beta ray attenuation method (mass concentration) Small and semi-permanent semiconductor detector is used to detect the Beta ray Easy calibration with the calibration film Meas. range 0 - 1000, 0 - 5000 μg/m3 (0 - 1, 0 - 5 mg/m3)

 Low-cost basic model  Easy-to-read large customized LCD display  External printer connectable  Data storage up to 300 points  Compliant with USP<645> requirements  Meas. range 0 - 200.0 S/m 0 - 20.00 MΩ・m Chloride 0 - 4.00% 0 - 100.0 degrees C

Compact DIN 96 size Conductivity meter with built-in microcomputer for various applications such as ultra-pure water production, boiler plants, foodstuff plants, etc. Two detectors connectable  RS-232 equipped as standard specification Output: 2-channel, insulated, 4 - 20mA Meas. range Minimum : 0 - 0.2 μS/cm Maximum: 0 - 20 mS/cm

Panel Type Electromagnetic Concentration Analyzer MBM-102A Compact DIN 96 size Conductivity of NaCl, HCl, H2SO4, etc. are measured and converted to concentration (%) data automatically Assignable measurement range 2-point contact signal, 4 - 20mA output (RS-232 optional) Examples of measurement ranges NaCl: 0 - 10% HCl: 30 - 40% H2SO4: 93 - 99.5% NaOH: 0 - 15%

Detector with Water Jet Cleaner JOC-711C / JOC-950C Cleaning electrode contamination by jetting water or air onto the electrode Immersion type (JOC-711C) and drop-in type (JOC-950C) Electrode: polarograph type 7533L (for standard use) or 7536L (for human waste)

Exchangeable Tip ORP Electrode PSS/ASS‐304B(KCl replenish-free) / PSS/ASS‐314B(KCl refillable) asy-to-replace electrode tip and  reference electrode junction tip Platinum electrodes (PSS) and gold electrodes (ASS) available KCl non-refillable type is ideal for wastewater treatment; KCl refillable type for processes Selection of electrode holder: immersion type, drop-in type and flow-through type Meas. range ORP: -2000 - +2000 mV