Drop-In Type Detector for Replaceable Tip Electrode HC-G95 (KCl Replenish-Free) Two selections: throw-in type for deep tanks or drop-in type with a protection pipe Made from transparent PVC (heat resistance: 60 degrees C) SUS protection pipe (maximum length: 5 m) and mounting bracket  available

Flow-Through Type Holder for Replaceable Tip Electrodes HC-G80 (KCl Replenish-Free/Refillable) / HC-G82 (KCl Replenish-Free/Refillable) HC-G80: Transparent holders made of PVC (heat resistance: 60 degrees C) ; maximum pressure resistance: 0.15MPa  HC-G82: PP/SUS316 part (heat resistance: 80 degrees C) and PVDF/SUS316 part (heat resistance: 100 degrees C) ; maximum pressure resistance: 0.3 MPa

Immersion Type Sensor with Pulse Air Jet Cleaner PHC-7D Immersion type pH/ORP electrode holder combined with pulse air jet cleaner Cleaning by high-speed water stream created by the rapid expansion of pulse-jetted compressed air in the sample water High cleaning effect due to air bubbles present in the water stream randomly hitting the electrode No consumables required, such as reagents, brushes

Industrial Low-Concentration DO Transmitter ODM-100A (2-wire) / ODM-110A (4-wire) Easy-to-use low-concentration DO analyzer for field installation in a compact and rigid aluminum case Simplified calibration procedure; auto detection of electrode deterioration Alterable output range Automated self-diagnosis of fault (burn-out output) Meas. range Minimum: 0 - 20 μg/L Maximum: 0 - 2000 μg/L

Low-Concentration DO Transmitter OBM-300 (4-wire) Multi-functional low-concentration DO analyzer for field installation in a compact diecast aluminum case 3 ranges (automatically switched), 2-point regulated output Alterable output range One-touch calibration and various self-diagnostic functions Meas. range Minimum : 0 - 20 μg/L Maximum: 0 - 999.9 μg/L

Panel Type Low-Concentration DO Transmitter OBM-100H Panel type low-concentration DO analyzer in a compact DIN 96 size 2-point regulated, 4 - 20mA, RS-232 output One-touch calibration and various self-diagnostic functions Power supply: 90~264VAC, 50/60Hz Meas. range Minimum : 0 - 20 μg/L Maximum: 0 - 1000 μg/L

Low-Concentration DO Detector for Pure Water OC-64 Suitable for low-concentration DO measurement (pure water in semiconductor factories, boiler water in power plants) Micro-flow (100mL/min) with special flow cell Electrode: polarograph type 7561L (Ag electrode) or 7563L (Au electrode) Lead wire: ELW-32

Industrial Conductivity Transmitter WDM-135A (2-wire) / WDM-136A (4-wire) Easy-to-use conductivity analyzer for field installation in a compact and rigid aluminum enclosure Wide application range from ultra-pure water to wastewater  Alterable output range Meas. range Minimum: 0 - 0.2 μS/cm Maximum: 0 - 20 mS/cm