• Filter

Frequency bandwidth:  DC to 10 MHz Maximum continuous input range: 150 Arms Functions with Digital Oscilloscopes, Scopecorders or other waveform measuring instruments.

Frequency bandwidth:  DC to 2 MHz Maximum continuous input range: 500 Arms Functions with Digital Oscilloscopes, Scopecorders and other waveform measuring instruments.

Frequency bandwidth:  DC to 100 MHz Maximum continuous input range: 30 Arms Functions with Digital Oscilloscopes, Scopecorders or other waveform measuring instruments.

Frequency bandwidth:  DC to 50 MHz Maximum continuous input range: 30 Arms Functions with Digital Oscilloscopes, Scopecorders or other waveform measuring instruments.

Model 2769 is a compact, portable Kelvin double bridge designed for measuring low resistance from 0.1 ohm to 110 ohm with four multiplication plugs and one measuring dial. It has built-in standard resistors, bridge power source and high-sensitivity taut-band suspension system electronic DC galvanometer.

Model 2755 measures resistances from 1 Ω to 10 MΩ by operation of dials and switches. Batteries and a galvanometer are self-contained. The front control panel is provided with power and galvanometer circuit selectors, one ratio arm, and four measuring dials. Model 2755 is also equipped with a Murray and Varley Loop Tester for convenient location of line faults such as "shorts" and "grounds" in power, telephone, telegraph, and signal cables. No auxiliary attachment required Galvanometer with a built-in protection circuit Compact, lightweight (2 kg) Built-in Murray & Varley loop tester

Laboratory-grade accuracy ±0.03 to ±0.05% Quick readout without error Excellent long-term stability: The resistance elements are made of selected manganin wire, stabilized by both artificial and natural aging after being wound. Perfect guard system Stable measurement: The dial switches offer low contact resistance and little change due to aging, giving stable operation. Inner/outer contact type plugs are used for changing the multiplication factor, assuring little change in the resistance due to reinsertion of plugs. Built-in standard resistors Bar resistor measurement

Model 2768 is a Precision bridge used for the exact determination of resistance in the 100 MΩ to the 110MΩ Range with an accuracy of 0.01 to 0.05%. Since this instrument includes a high-sensitivity transistorized galvanometer and bridge power source, no auxiliary device is required. Superior resistor aliment Minimized contact resistance Guarding and shieldingMaterials of high insulation resistance and low absorption are employed. Guard circuits are provided to insure stable operation even In highly humid atmospheres. The instrument is housed in a {grey} metal case to assure -to operator of excellent shielding. Heat-insulated pushbutton keysIf the operator's body temperature were carried to the galvanometer sensitivity control keys, a temperature difference would arise at the contact point and produce thermal EMF resulting in measurement error. To eliminate this effect, the pushbutton keys for the galvanometer sensitivity control are heat-insulated with phenol resin.