Displays temperature and relative humidity / wet bulb temperature / dewpoint Max./min. values Hold button to freeze readings Display light Auto Off function TopSafe, the indestructible protection case (optional) Patented humidity sensor 2 year guaranteed long-term stability TopSafe, instrument protection against dirt and knocks (optional) Go for TST0191 if you do not need a cable  

humidity/temperature instrument, incl. plug-in humidity probe head, battery and calibration document Displays temperature and relative humidity / wet bulb temperature / dewpoint Max./min. values Hold button to freeze readings Display light

Humidity and temperature measuring instrument incl. protective cap, batteries and calibration protocol TST0102 measures relative air moisture and temperature simultaneously. Dew point calculation and wet bulb as well as Hold function and max./min. display are possible with this instrument. Long-term stable Testo humidity sensor +/-2.5 %RH accuracy Incl. calibration protocol Dewpoint calculation and wet bulb included Hold function and max./min. values Protective cap for safe storage Belt case, wrist strap and calibration protocol included Backlit display Air moisture and air temperature Storage temperature -40 to +70 °C Operating temperature -10 to +50 °C Battery type 2 batteries Type AAA Battery life 200 h Weight 90 g Dimensions 119 x 46 x 25 mm Probe type NTC Meas. range -10 to +50 °C Accuracy ±0.5 °C Resolution 0.1 °C Probe type humid. sensor, cap. Meas. Range 0 to 100 %RH Accuracy ±2.5 %RH (5 to 95 %RH) Resolution 0.1 %RH

TST0100; wood and building material moisture meter, incl. protective cap, batteries and calibration protocol 606-1 measures material moisture. Material moisture is displayed in percent by weight using stored material characteristic curves for wood and building materials. Accurate wood moisture measurement with stored characteristic curves for beech, spruce, larch, oak, pine, maple Additional characteristic curves to locate wet points in building materials for cement screed, concrete, plaster, anhydrite screed, cement mortar, lime mortar, brick Hold function for easy readout of readings Display illumination Self-test function Protective cap for safe storage Belt case, wrist strap and calibration protocol included Made in Germany Latest technology Storage temperature -40 to +70 °C Operating temperature -10 to +50 °C Battery type 2 batteries Type AAA Battery life 200 h Weight 90 g Dimensions 119 x 46 x 25 mm Probe type Conductive measurement cell Meas. Range 0 to 50 % Accuracy ±1 % Resolution 0.1 Additional benefits for TST0101: Measurement of temperature and humidity in ambient air Air humidity...

Multi-point or timed mean calculation Stores up to 99 file locations Logger function (3000 readings) Quick documentation on site on the Testo printer  

Light intensity measuring instrument incl. protective cap, batteries and calibration protocol   The sensor of the TST0093 is adapted to the spectral sensitivity of the eye. This makes testo ideal for the measurement of light intensity. The Hold function allows an easy readout of the measurement values. Max. and min. values are displayed at the press of a button. TST0093 is very handy, small and easy to operate. Hold function and max./min. values Incl. calibration protocol Protective cap for safe storage Including wrist strap and belt holder Sensor adapted to spectral sensitivity of the eye Display light Storage temperature -40 to +70 °C Operating temperature 0 to +50 °C Battery type 2 batteries Type AAA Battery life 200 h Weight 95 g Dimensions 133 x 46 x 25 mm Probe type Lux Meas. Range 0 to 99,999 Lux Accuracy ±3 % Resolution 1 Lux (0 to...

TST0092 535, CO2 measuring instrument with permanently attached probe, batteries and calibration protocol Long-term stable 2 channel infrared sensor Highly accurate, highly efficient Repeated calibration is unnecessary TST0092 535, CO2 measuring instrument with permanently attached probe, batteries and calibration protocol Long-term stable 2 channel infrared sensor Highly accurate, highly efficient Repeated calibration is unnecessary

differential pressure meter, 0 to 2000 hPa, incl. battery and calibration protocol 8 switchable units of pressure: kPa, hPa, Pa, mm H2O, mmHg, psi, inch H2O, inch Hg Integrated density compensation Display illumination Hold-/max-/min function Printout of measurement values incl. date/time and min/max values Storage temperature -10 to +70 °C Operating temperature 0 to +60 °C Battery type 9V block battery, 6F22 Battery life 120 h Weight 300 g Dimensions 202 x 57 x 42 mm Material/Housing ABS Probe type Pressure sensor integrated Meas. Range 0 to +2000 hPa Accuracy 0.5% of fsv Resolution 1 hPa