MadgeTech’s IFC200 interface cable communicates between stand alone data loggers and the MadgeTech software. Through this interface, loggers can be started, stopped or downloaded. The IFC200 has been redesigned, and is now “plug and play”. It can be directly connected to a computer without installing any drivers and is compatible with Windows XP SP3, Windows Vista (32 and 64 bit), and Windows 7 (32 and 64 bit) operating systems. The improved IFC200 can now operate at up to 500 Volts RMS relative to the computer’s earth ground when attached. The IFC200 is equipped with communication LEDs, that provide a quick indication of the device status. The blue light illuminates when the device is plugged in and successfully recognized by Windows. The red light flashes when data is sent, and the green light flashes when data is received.

MadgeTech’s IFC202 interface cable communicates between the Micro series data loggers and the MadgeTech software. Through this interface, loggers can be started, stopped or downloaded. The IFC202 has been redesigned, and is now “plug and play”. It can be directly connected to a computer without installing any drivers and is compatible with Windows XP SP3, Windows Vista (32 and 64 bit), and Windows 7 (32 and 64 bit) operating systems. The improved IFC202 can now operate at up to 500 Volts RMS relative to the computer’s earth ground when attached. The IFC202 is equipped with communication LEDs, that provide a quick indication of the device status. The blue light illuminates when the device is plugged in and successfully recognized by Windows. The red light flashes when data is sent, and the green light flashes when data is received. The IFC202 is compatible with the MicroTemp, MicroRHTemp, EggTemp, EggTemp-RH and EGMS.

Interface cable package for the TransiTemp and Cryo-Temp Series Data Loggers. Includes MadgeTech Software CD, Software Manual, Quick Start Guide, USB cable and USB Docking Station.

Interface Cable Package for the HiTemp140 and PR140 Data Loggers. Includes MadgeTech Software CD, Software Manual, Quick Start Guide, USB Cable and USB Docking Station.

The IFC406 Multiplexer Data Logger Interface allows for multiple devices to be connected into one interface. Each IFC406 allows for 6 data loggers to be connected. Up to 3 IFC406 units may be daisy-chained together to communicate with a total of 18 devices through 1 USB port. Includes MadgeTech Software, Software Manual, Quick Installation Guide, USB Cable and IFC406 Multiplexer Data Logger Interface.

Wireless transceiver for the RFOT, Therm-A-Lert and RF2000A Series of Data Loggers. Includes MadgeTech Software, Software Manual, Quick Start Guide, USB to mini USB adapter and RFC1000 wireless transceiver. The new design includes a higher powered transceiver and a substantially longer transmit range, meaning better performance in all environments. This RFC1000 features a 7" pivoting external antenna, which increases the transmission distance and provides greater signal strength. The pivoting antenna also allows more flexibility with mounting orientation. The RFC1000 can be used as a repeater or plugged directly into your PC.

MadgeTech's new RFC1000-CE is a powerful wireless receiver for use with the RFOT, Therm-A-lert and RF2000A Series of data loggers and is CE approved for the European market. The RFC1000-CE transmits to other RFC1000-CEs up to 2500 feet outdoors/line of sight, 700 feet typical indoors/urban. The RFC1000-CE transmits to data loggers up to 2000 feet outdoors/line of sight, 500 feet typical indoors/urban. Additional RFC1000-CEs can be used as repeaters to transmit greater distances. This new RFC1000-CE also includes an external antenna, allowing more flexibility with mounting positions in both orientation and proximity to metal walls. This may be used as a repeater, or directly plugged into the PC.

Splash proof wireless transceiver for the RFOT, Therm-A-Lert and RF2000A Series of Data Loggers. Includes MadgeTech Software, Software Manual, Quick Start Guide, USB to mini USB adapter and RFC1000-IP69K wireless transceiver. This new splash proof transceiver can be installed directly in the wash down location, ensuring 100% communication throughout the entire process. MadgeTech has gone through extensive testing to ensure that the new RFC1000-IP69K can withstand wash down cycles using caustic chemicals, making it ideal for harsh environments. This model includes a high powered transceiver with an IP69K ingress protection rating. The RFC1000-IP69K has a substantial transmit range, providing better performance in occluded environments such as ovens and refrigerators. This new The RFC1000-IP69K also includes an external antenna which is protected by a neoprene boot, allowing more flexibility with mounting positions in both orientation and proximity to metal walls. The RFC1000-IP69K is designed to communicate between MadgeTech’s two-way wireless data loggers and the MadgeTech software and can connect to a maximum of 64 data loggers.