SEW-Taiwan

Insulation Testers

  • Filter

FEATURES ● Microprocessor-controlled.● Measures insulation (MΩ), Continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm (2.677” × 1.338” ) large LCD display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 200mA short circuit testing current for continuity.● Auto ranging.● Fuse protection.● Data hold function● BS 16 edition.     SPECIFICATIONS   Insulation Resistance     Test voltage 250V / 500V / 1000V Measuring ranges (Auto ranging) 0-2MΩ / 0-20MΩ / 0-200MΩ / 0-2000MΩ Output voltage open circuit +10% Accuracy 0-2MΩ : ±(5%rdg+5dgt) 0-20MΩ : ±(1.5%rdg+5dgt) 0-200MΩ : ±(2.5%rdg+3dgt) 0-2000MΩ : ±(5%rdg+5dgt) Resolution 0-2MΩ : 1kΩ 0-20MΩ : 10kΩ 0-200MΩ : 100kΩ 0-2000MΩ : 1MΩ Output current 1mA DC AC Voltage     Range 0-600V  Resolution 1V Line frequency range 40-120 Hz Accuracy ±(1.5%rdg+3dgt) Current for...

FEATURES ● Measures insulation (MΩ), Continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm (2.677” × 1.338” ) large LCD display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 210mA short circuit testing current for continuity.● External voltage warning indication.● Fuse protection.● BS 16 edition     SPECIFICATIONS   Insulation Resistance     Test voltage (DC V) 250V / 500V 1000V Measuring ranges 0-200MΩ  0-2000MΩ Resolution 1 count / 100kΩ 1 count / 1MΩ Accuracy ±(1.5%rdg+5dgt) ±(3%rdg+3dgt) (under 1GΩ/2000MΩ) ±(5%rdg+3dgt) (under 2GΩ/2000MΩ) Output voltage on open circuit Rated test Voltage +10% Output current 1mA DC Power consumption 250mA  Continuity     Measuring range 0-20Ω    0-2kΩ Accuracy ±(1.5%rdg+5dgt) ±(1.5%rdg+3dgt) Resolution 0.01Ω      1Ω Buzzer sound...

FEATURES ● Timer for test function (count 3-5 minutes).● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm (2.677” × 1.338”) large LCD display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 200mA short circuit testing current for continuity.● External voltage warning indication.● Fuse protection.● Data hold function● Auto power off function.● BS 16 edition.     SPECIFICATIONS   Insulation Resistance     Test voltage (DC V) 250V / 500V / 1000V Measuring ranges (Auto ranging) 0-20MΩ / 0-200MΩ / 0-2000MΩ Accuracy 0-20MΩ : ±(1.5%rdg+5dgt) 0-200MΩ : ±(2.5%rdg+3dgt) 0-2000MΩ : ±(5%rdg+5dgt) Output voltage on open circuit Rated test Voltage +10% Output current 1mA DC Power consumption 250mA  Continuity     Measuring range 0-20Ω / 0-200Ω / 0-2000Ω Accuracy ±(1.5%rdg+3dgt) Resolution 0.01Ω / 0.1Ω / 1Ω Buzzer sound below under 10Ω Open circuit terminal voltage 4V DC...

FEATURES ● Microprocessor-controlled.● 68 × 34mm(2.677” × 1.338”) large LCD display.● 3½ digital LCD(2000 counts) a LCD indicated instrument for    insulation.(MΩ), continuity(Ω) and AC voltage.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA DC load.● >200mA short circuit testing current for a resistance tests.● Auto ranging.● REL function.● Auto power OFF.● Fuse protection.● Auto data hold.● BS 16 edition.     SPECIFICATIONS   Insulation Resistance     Test voltage (DC V) 250V / 500V / 1000V Measuring ranges (Auto ranging) 0-2MΩ / 0-20MΩ / 0-200MΩ / 0-2000MΩ Output voltage on open circuit +10% Accuracy 0-2MΩ : ±(5%rdg+5dgt) 0-20MΩ : ±(1.5%rdg+5dgt) 0-200MΩ : ±(2.5%rdg+3dgt) 0-2000MΩ : ±(5%rdg+5dgt) Resolution 0-2MΩ : 1kΩ 0-20MΩ : 10kΩ 0-200MΩ : 100kΩ 0-2000MΩ : 1MΩ Output current 1mA DC AC Voltage     Range 0-600V Resolution 1V Line frequency...

FEATURES ● Microprocessor-controlled with advanced safety features.● Three test voltages : 250 / 500 / 1000V.● Displays and sound warning if external voltage present.● Ener-Save™ feature to extend battery life.● Continuous battery monitoring.● Auto ranging / auto-null / auto-off.● Insulation tested at 1mA.● Built-in carry case, test leads in separate pouch.● Real-time barg-raph display of test voltage and voltage decay during    discharge.● Audible and visual message displayed if external voltage is present.● Large LCD.● Display can be customized for special orders.● Continuity buzzer.● Show test time duration (up to 99.9s) for easy comparison.● BS 16 edition.     SPECIFICATIONS         Insulation Resistance     Test voltage (DC V) 250V     /     500V     /   1000V Measuring ranges (Auto ranging) 0-1000MΩ / 0-2000MΩ / 0-3000MΩ Accuracy ±3%rdg Output current 1mA DC min at 0.25MΩ(250V) 1mA DC min at 0.5MΩ(500V) 1mA DC min...

FEATURES ● High quality Taut Band movement.● Measures insulation(MΩ) and AC voltage.● LED indiction for testing insulation.● Highly efficiency and accurate DC-DC converter.● Battery check function.● Compact and lightweight.● AC voltage measurement can be made without depressing the test    button.     SPECIFICATIONS   Insulation Resistance     Test voltage (DC V) 100V Output voltage on open circuit Rated test voltage +10% Measuring ranges 0-200MΩ Mid-scale value 5MΩ Accuracy 0.2-100MΩ : ± 5% rdg 0.7% of scale length at other ranges Short circuit current 1mA DC AC Voltage     Range 0-500V Accuracy ± 2.5% of full scale General     Operating temperature & humidity 0°C ~ 40°C relative humidity up to 85% Storage temperature & humidity -10°C ~ 50°C relative humidity up to 85% Dimensions 175(L) × 85(W) × 75(D) mm Weight (battery included) Approx. 510g Power source 1.5V (AA) × 4 Safety standard EN...

FEATURES ● High quality Taut Band movement.● Battery operated.● Solid state circuitry.● Battery check feature.● Automatic circuit discharge.● Three insulation test voltages.● Color-coded scale.● AC voltage measurement.● Fuse protected.   SPECIFICATIONS   Insulation Resistance     Test voltage (DC V) 50V   /   125V   /   250V Measuring ranges 0-20MΩ / 0-50MΩ / 0-100MΩ Output voltage on open circuit Rated test voltage +10% Accuracy ±5% of indicated value Short circuit terminal current 2mA DC Power consumption 190mA Continuity     Measuring range 0-50Ω & ∞ Accuracy ± 5% of scale length Open circuit terminal voltage 445mV DC Approx. Short circuit terminal current 145mA DC Approx. Power consumption 200mA AC Voltage     Range 0-600V AC Accuracy ± 2.5% of full scale Line frequency range 40-1kHz General     Dimensions 170(L) × 165(W) × 92(D) mm Weight ...

FEATURES ● High contrast OLED display● Designed for viewing in the dark, for mining industry.● Wide viewing angle.● Smart microprocessor-controlled.● 2 x 16 characters, large, High Contrast, Intelligent OLED Display.● Automatically calculates Delectric Absorbtion Ration (DAR).● Automatically calculates Polarization Index (PI).● Insulation resistance; Auto-ranging on all ranges.● Ener-Save● Bar graph indicates test voltage. Rise and decay can be obeserved.● External voltage presence warning (>500Vac or Vdc)● Overload protection● Low battery indicator (real time battery voltage mearsurement)● Measures insulation time duration of the test● Better than 10% accuracy on all ranges● Auto-off   SPECIFICATIONS   Test voltage From 500Vdc to 10kVdc Adjustable in 500V Steps Preset buttons 1kV, 2.5kV, 5kV, 10kV Measuring range 800kΩ-500GΩ (auto-ranging) Accuracy ±5% ± 2 digits Output power limit 1W Voltage regulation Selected Voltage +20%-5% of nominal value unless current limited. Meaning that if output current is too high, the voltage will...