FEATURES ● Microprocessor-controlled.● Indicates phase rotation.● Indicates phase presence.● Tests for disconnection sensitivity.● Indicates battery status.● Tests for disconnection time.● Measures voltage phase to earth.● Select one of 3 Phase to test ELCB.● Color-coded test leads.● Phase presence indication from as low as 100Vac.● Very low consumption.● Fused earth leakage tester.● ELCB works 50Vac to 330Vac 50Hz / 60Hz.● Led indication of Voltage on ELCB.● Phase rotation and presence does not require battery to indicate.● EN 61010-1 CAT III 550V. EN 61326-1     SPECIFICATIONS     Determination of the Phase Presence     Nominal Voltage for Phase Presence Indication (the voltage required for the neon lamps L1, L2, L3 to lit up) From 100Vac to 450Vac. Frequency Range From 10Hz to 400Hz. Determination of the Phases Rotary Field Direction   Direction (the voltage required to have the direction LEDs L1-L2-L3 or L2-L1-L3 to indicates) From 100 to 450Vac. Frequency Range From 2Hz to...

FEATURES ● High contrast OLED display.● Designed for viewing in the dark, for mining industry.● Microprocessor-controlled.● Indicates phase rotation● Indicates phase presence● TEST for disconnection sensitivity● Battery status indicator● Measures Voltage Phase to Earth● Select one of 3 Phase to test ELCB.● Color-coded test leads.● Phase presence indication from as low as 100Vac.● Fused earth leakage tester.● ELCB works 50Vac to 330Vac 50Hz / 60Hz.● Phase rotation and presence does not require battery to indicate.     SPECIFICATIONS       Nominal voltage for phase presence frequency range 100Vac to 450Vac 10Hz to 400Hz Rotary field direction phases frequency range 100 to 450Vac 2Hz to 400Hz Overload protection 550V (between all terminal) Over voltage protection Class III - 450V towards ground Current settings 999mAac /50Hz-60Hz Phase start selection 0º and 180º Phase polarity trip Indicator ˇ Operating voltage (L-E) referenced to earth 220Vac to 317Vac Timer resolution 1ms (Max....

FEATURES ● Wiring check.● Can be used on 2 wires L-E (ELCB/RCCB/GFCI tester).● Can be used on 3 wires L-E-N (with wiring check).● Sense automatically 50 or 60 Hz.● No battery required.● Simple operation.● Current injected in phase with the voltage.● Fused.● Wide operating voltage (195Vac to 265Vac).● Other voltage optional (110V).● Robust.     SPECIFICATIONS         Wiring check LEDs Line-Neutral = Green Line-Earth = Green Neutral-Earth =Red Current settings 10-50mA@230Vac> Current selection Knob Frequency of operation 50/60 Hz Sinusoidal Over-Temperature Protection Yes by NTC sensor Test stopped indication by Red Led. Operating voltage (L-E) 230 Vac ±15% Meter accuracy ±3% of full scale Operating temperature -5°C to 45°C Storage temperature -10°C to 55°C Dimensions 150(L) × 73(W) × 50(D)mm Weight Approx. 220g Safety standard EN 61010-1 CAT III 265V EN 61326-1

FEATURES ● Mains wiring polarity check.● ELCB/RCD testing.● Measuring ear for line current.● Measuring ear for leakage current.● Helps calculate insulation resistance.● Helps calculate power consumption.● Helps fault finding of standing earth fault.● Fused main adapter.● Appliance testing (with the aid of a clamp meter).● Fused appliance socket.● No batteries required.● HRC fuse inside.● Fused, color-coded universal test sockets.● Universal mains IEC Lead.     SPECIFICATIONS       Voltage / power input     Universal IEC LEAD 240V/10A Wiring polarity check     Nominal Voltage 240Vac Frequency 50/60Hz Mains Voltage Tolerance ±10% Elcb / rcd tester     Nominal Voltage 240Vac Frequency 50/60Hz Current Tolerance (current proportional to Line to Earth Voltage) ±10% Universal test sockets     Nominal Voltage 240Vac Frequency 50/60Hz Mains Voltage Tolerance ±10% Fuse 10A Appliance tester     Nominal...

FEATURES ● The TEL1 is the Basic Test Equipment an Electrician cannot do   without. TEL1 is a Dual Function Test Instrument utilized to Verify   Electrical Wiring Connections and the Functioning of Earth Leakage   / Residual Current Detectors devices by forcing the ELCB/RCD to   trip.     SPECIFICATIONS         Nominal Voltage System 110V-220V-230V-240Vac available - User Selectable at purchase. System Voltage Frequency 50-60Hz Wiring Check Accuracy Table Valid for Voltage within 5% of nominal voltage. If voltage differs from Nominal Voltage System by more than 5%, table may be incorrect. Earth / Ground Current Simulator Accuracy Current is set by Selected Resistors and therefore Proportional to Voltage. Resistance Accuracy is 10% Maximum. Overall Rating Intermittent Rated (Press TEST Shortly). DO NOT KEEP PRESSING TEST. Resistance Rating Current Injection System uses Resistors which are Not Continuously Rated. Case Material ABS Safety Standard EN 61010-1 EN...