SEW-Taiwan

Clamp Meters

  • Filter

FEATURES ● Designed for testing AC current and AC voltage.  ● 5 ranges for AC current testing. ● The best resolution of leakage current measurement is 0.1mA.● Frequency selection : 50/60 Hz and Wide.● Data hold function.● Maximum reading.● Low battery indication.     SPECIFICATIONS       AC Current     Ranges Accuracy 50/60Hz WIDE 200mA(0~199.9mA) ±(1.5%rdg+2dgt) 40/1000Hz : ±(3.0%rdg+2dgt) 2A (0~1.999A) 20A(0~19.99A) 200A(0~199.9A) ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 0-500A ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 501-1000A ±5.5%rdg 40/1000Hz : ±10%rdg AC Voltage      Ranges AC600V / DC600V Resolution 1V /1V Accuracy ±(1.5%rdg+3dgt)/ ±(1.0%rdg+2dgt) GENERAL   Conductor size 55mm Max. Operating principle Dual slope integration Display 3½ digit (2000 counts) Low battery indication “  “ sign appears on the display when the battery voltage drops below accurate...

FEATURES ● Designed for testing AC current and AC voltage.  ● 5 ranges for AC current testing.● The best resolution of leakage current measurement is 0.1mA.● Frequency selection : 50/60 Hz and Wide.● Data hold function.● Maximum reading.● Low battery indication.     SPECIFICATIONS       AC Current     Ranges Accuracy 50/60Hz WIDE 200mA(0~199.9mA) ±(1.5%rdg+2dgt) 40/1000Hz : ±(3.0%rdg+2dgt) 2A (0~1.999A) 20A(0~19.99A) 200A(0~199.9A) ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 0-500A ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 501-1000A ±5.5%rdg 40/1000Hz : ±10%rdg AC Voltage      Ranges AC 200V/AC600V Resolution 0.1V / 1V Accuracy ±(1.5%rdg+3dgt) GENERAL   Conductor size 55mm Max. Operating principle Dual slope integration Display 3½ digit (2000 counts) Low battery indication “ “ sign appears on the display when the battery voltage drops below accurate operating   level ...

FEATURES ● 4000 - count LCD.● Full automatic measurement.      ◎ Voltage measurement.      ◎ Current measurement.      ◎ Resistor measurement.      ◎ Capacitor measurement      ◎ Frequency counter.● Range change function.● Data Hold function freezes the reading.● Continuity check.● Diode measurement.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded    banana plugs and recessed input terminals.     SPECIFICATIONS         AC A 400.0/2000A (40~500Hz) 0~1500A           ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt) AC V 400.0mV ±(2.0%rdg+3dgt) 4.000/40.00/400.0/750V ±(1.5%rdg+3dgt)     40~500Hz DC A 400.0/2000A 0~1500A           ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt) DC V 400.0mV/4.000/40.00/400.0/1000V...

FEATURES ● 2000 - count LCD.● Full automatic measurement.          ◎ Voltage measurement.          ◎ Current measurement.          ◎ Resistor measurement.          ◎ Capacitor measurement          ◎ Frequency counter.● Range change function.● Data Hold function freezes the reading.● Continuity check.● Diode measurement.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded    banana plugs and recessed input terminals.     SPECIFICATIONS         AC A 200.0/2000A (40~500Hz) 0~1500A           ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt) AC V 200.0mV ±(2.0%rdg+3dgt) 2.000/20.00/200.0/750V ±(1.5%rdg+3dgt) 40~500Hz DC A 200.0/2000A...

FEATURES ● 4000- count LCD.● Full automatic measurement.           ◎ Voltage measurement.           ◎ Current measurement.           ◎ Resistor measurement.           ◎ External frequency measurement.● Range change function.● Data Hold function freezes the reading.● REL function.● Peak function.● VAHz mode measures frequency in ACV and ACA mode.● Max/Min function.● Continuity check.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded   banana plugs and recessed input terminals.     SPECIFICATIONS         AC A 400.0/2000A (40~500Hz) 0~1500A           ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt) AC V 400.0mV ±(1.5%rdg+3dgt) 4.000/40.00/400.0/750V ±(1.0%rdg+3dgt)     40~500Hz DC A 400.0/2000A...

FEATURES ● Full auto range for V.A and Ω functions.● Data hold function freezes the reading in dimly lit or hard to reach    places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded    banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers    and motor coils.     SPECIFICATIONS         AC A 400A / 1000A ±(1.5%rdg+3dgt) : 40-500Hz AC V 400V / 600V ±(1.0%rdg+3dgt) : 40-500Hz DC A 400A / 1000A ±(1.5%rdg+3dgt) DC V 400V / 600V ±(0.75%rdg+3dgt)   Ω 400Ω / 2000Ω ±(1.0%rdg+3dgt) Flashlight   ─── LCD backlight display   ─── Buzzer sounds    <38Ω Conductor size 40mm Max. Low battery Indication   Dimensions 255(L) × 80(W) × 35(D)mm Weight (battery included) Approx. 420g Power source 9V(6F22) × 1 Safety standard EN 61010-1 CAT III 600V EN...

FEATURES ● Full auto range for V.A and Ω functions.● LCD backlight display.● Flashlight function.● Data hold function freezes the reading in dimly lit or hard to reach    places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded   banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers   and motor coils.     SPECIFICATIONS             AC A 400A / 1000A ±(1.5%rdg+3dgt) : 40-500Hz AC V 400V / 600V ±(1.0%rdg+3dgt) : 40-500Hz DC A 400A / 1000A ±(1.5%rdg+3dgt) DC V 400V / 600V ±(0.75%rdg+3dgt)   Ω 400Ω / 2000Ω ±(1.0%rdg+3dgt) Flashlight   ˇ LCD backlight display  ˇ Buzzer sounds    <38Ω Conductor size 40mm Max. Low battery Indication   Dimensions 255(L) × 80(W) × 35(D)mm Weight (battery included) Approx. 430g Power source 9V(6F22) × 1 Safety...

FEATURES ● Full auto range for V.A and Ω functions.● Data hold function freezes the reading in dimly lit or hard to reach   places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded   banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers   and motor coils.     SPECIFICATIONS         AC A 400A / 1000A ±(1.5%rdg+3dgt) : 40-500Hz AC V 400V / 600V ±(1.0%rdg+3dgt) : 40-500Hz DC A 400A / 1000A ±(1.5%rdg+3dgt) DC V 400V / 600V ±(0.75%rdg+3dgt)   Ω 400Ω / 2000Ω ±(1.0%rdg+3dgt) Flashlight   ─── LCD backlight display   ─── Buzzer sounds    <38Ω Conductor size 40mm Max. Low battery Indication   Dimensions 255(L) × 80(W) × 35(D)mm Weight (battery included) Approx. 420g Power source 9V(6F22) × 1 Safety standard EN 61010-1 CAT III 600V EN...