SEW-Taiwan

Various Instruments

  • Filter

FEATURES ● Microprocessor-controlled.● Four terminal measurement.● Measures down to 100μΩ.● 5 Ranges from 200.0mΩ to 2000Ω.● Maximum resolution of 100μΩ.● Three test currents with over-temperature protection.● Protection against inadvertent connection to over voltage.● Large LCD.● Potential lead resistance and current lead resistance checks.● "Full-featured” EnerSave inside.● EnerSave Auto hold.● EnerSave Auto off.● Lightweight, robust & compact.● Indicators show if reading may be invalid (RP, RC, and     temperature).● "O-Ring” sealed case.     SPECIFICATIONS         Measuring ranges 0-200.0mΩ in steps of 100μΩ 0-2000mΩ in steps of 1mΩ 0-20.00Ω in steps of 10mΩ 0-200.0Ω in steps of 100mΩ 0-2000Ω in steps of 1Ω Accuracy ±0.5% of reading ±2 digits over the operating temperature range, -15ºC to +55ºC, with the supplied test leads Test current 1mA=>2000Ω range 10mA=>200 / 20Ω ranges 100mA=>2000m / 200mΩ ranges Test current accuracy ±0.1% Protection fuses Mains = 0.5A,...

FEATURES ● Microprocessor-controlled.● Measure down to 1μΩ.● 6 ranges from 2.000mΩ to 200.0Ω.● Maximum resolution of 1μΩ.● Three test currents with over-temperature protection.● Four terminal measurement.● Protection against inadvertent connection to over-    voltage. (crow bars for current and voltage)● Clear & large LCD.● Potential lead resistance and current lead resistance checks.● "Full-featured” EnerSave™ Inside.● EnerSave™ Auto-hold.● EnerSave™ Auto-off.● Rechargeable battery operated● Robust & compact.● Indicators show if reading may be invalid (RP, RC, and     temperature).● "O-Ring” sealed case.     SPECIFICATIONS       Low resistance ranges / resolution 0-2.000mΩ / 1μΩ 0-20.00mΩ / 10μΩ 0-200.0mΩ / 100μΩ 0-2.000Ω / 1mΩ 0-20.00Ω / 10mΩ 0-200.0Ω / 100mΩ Accuracy 0-2.000mΩ : ±(5%rdg+5dgt) 0-20.00mΩ : ±(4%rdg+4dgt) 0-200.0mΩ : ±(4%rdg+4dgt) 0-2.000Ω : ±(3%rdg+4dgt) 0-20.00Ω : ±(2%rdg+4dgt) 0-200.0Ω : ±(2%rdg+4dgt) Test current (dc) 2.000mΩ to 200.0mΩ :...

FEATURES ● High quality movement.● Compact and lightweight; easy to use and store.● Mirror scale: for easier viewing & reading.● Built-in stand makes reading and measuring easy.● 200μA full scale value.● Fuse-protected.● Low battery indication.     SPECIFICATIONS   AC Leakage Current     Measuring range 0.3mA-1mA-3mA-10mA-30mA Accuracy ±2% of full scale Input resistance 1.5kΩ AC Voltage     Measuring range 0-300 / 0-600V Accuracy ±2% of full scale Input resistance 300V     1MΩ 600V     2MΩ General     Low battery indication Battery check indicate good battery from 7Vdc to 9Vdc during a load test of 2mA Dimensions 160(L) × 100(W) × 45(D)mm Weight (battery included) Approx. 360g Power source 9V(6F22) × 1 Safety standard EN 61010-1 CAT III 600V EN 61326-1

FEATURES ● Bright LED and audible alarm sound when voltage is present.● Designed for non-contact voltage detection.● Can be used to find a break in a wire.● Flashlight function.● ON/OFF switch for longer battery life.     SPECIFICATIONS       Voltage detection 50V~1000V AC Frequency 50~500 Hz Measurement category CAT III 600V Indication LED and Tone Operating conditions Temperature : 0~40°C Humidity : Less than 80% R.H. Altitude : 2000m maximum For indoor use only ˇ Pollution degree 2 Dimensions 142(L) × 28(W) × 27(D)mm Weight (battery included) Approx. 45g    Power source    1.5V (AAA) × 2 Safety standard EN 61010-1 CAT III 600V EN 61326-1

FEATURES ● No batteries required.● Every circuit is doubled.● Buzzer indicates voltage detected.● Led indicates voltage detected.● Neon scale indicates voltage.● Dual HBC fuses.● High grade fiber glass probes.● Super polished fiber glass.● High strength connecting cord.● Heavy duty rated.● Replaceable tips.● Choice of tips available.● Lightweight.● Small storage space.● Strong strength reliefs.● Double poles non-polarized.● Suitable for 45 to 70 Hz networks.● Contact detector type.● Passive circuitry.● Fiber glass 1.6mm - CU 35um PCB.● Super bright neon lights and LEDs.● Ergonomically-designed.● EN 61010-031 CAT IV 500V.     SPECIFICATIONS       GENERAL     Maximum Rating between Poles 450V Category IV FUSES     Type HBC/HRC Rate of Rupture Slow Blow Current Rating 500mA    Voltage Rating 600V Quantity 2 VOLTMETER The Neon Voltage Scale Indication Neon lit when Voltage > or = 110V Neon lit when Voltage > or = 220V Neon...

FEATURES ● Voltage test: 12V to 690V AC/DC (7 LEDs) with indication by   buzzer.● Voltage range: 12V, 24V, 50V, 127V, 230V, 400V, 690V.● Polarity test: LED +/-● Audible continuity test● Self-test button to ensure proper function of the device prior to   testing.● Waterproof design, protection class: IP54● Phase / Neutral identification● Integrated storage clips for test probe.● Rubberized injection molding.     SPECIFICATIONS       Voltage test 12V to 690V AC/DC Voltage range AC : 12V,24V,50V,127V,230V,400V,690V DC : 12V,24V,50V,127V,230V,400V,690V Flashlight ––– Working frequency 40 to 400 Hz Voltage protection 1000V DC / 700V AC Continuity range 6kΩ Resistance range 6kΩ,60kΩ,300kΩ Operating temperature 0℃ to 40℃ Operating humidity 80% R.H. Probe distance 19mm apart Dimensions 206(L) x 58(W) x 42(D)mm Weight (battery included) Approx. 190g Power source 9V(6F22) x 1 Safety standard EN 61010-1 CAT III 600V EN 61243-3 EN...

FEATURES ● 4-20mA (1kΩ load, 24V Loop Supply).● 0.025% Basic Accuracy.● Simple Operation Interface.● Auto Ramp and Step Functions.● 0-20mA, 0-24mA selectable.● Incremental percentage setting : 0-100%.● Warning beeper when output is open.● 0-24V output.● The minimum load of 20kΩ on voltage mode.     SPECIFICATIONS   DC Current (1kΩ Max Load, 24v Loop Supply) Range 0-4mA / 4-20mA / 20-24mA Resolution 1uA Accuracy ±0.025%±10uA / ±0.025%±5uA / ±0.025%±5uA Beeper warning when output circuit is open and specified output voltage > 24V. DC Voltage (Approx. 10MΩ load) Range 0-4V / 4-20V / 20-24V Resolution 1mV Accuracy ±0.05%±10mV / ±0.05%±5mV / ±0.05%±5mV Beeper warning when voltage is short and specified output current is > 24mA. General     Power consumption 150mA at 24V 1kΩ load Operating temperature 0º C - 40º C Operating humidity   ≤ 80% R.H. Storage temperature -10º C - 50º C Storage humidity   ≤ 85% R.H. Dimensions ...

FEATURES ● Max. & Min. function.● Over & under range indication.● 4-digit LCD with bar graph.● Frequency weighting characteristic for 2 times per second.● AC signal output.● Low battery indication.     SPECIFICATIONS         Measuring ranges Lo :   30dB~80dB Med : 50dB~100dB Hi :   80dB~130dB Accuracy ± 1.5dB(at Reference Range) Reference sound level & frequency 94dB, 1kHz Resolution 0.1dB Detector-indicator characteristic Fast : 125ms Slow : 1s Analogue signal output AC 1Vrms for each range Dimensions 235(L) x 58.4(W) x 34(D)mm Weight (battery included) Approx. 220g Power source 9V(6F22) × 1 Safety standard   IEC 651 Type 2 &   ANIS S1.4 Type 2  EN 61326-1