Fluke

  • Filter
Category: ScopeMeters

Dual-input 40 MHz or 20 MHz digital oscilloscope Two 5,000-count true-rms digital multimeters A dual-input TrendPlot™ recorder Connect-and-View™ trigger simplicity for hands-off operation Shielded test leads for oscilloscope, resistance and continuity measurements Industrial Networks bus health testing Measure harmonics and power, VA, VAR, W, PF Up to seven hours battery operation 600 V CAT III safety certified Optically isolated RS-232 interface Rugged compact case Bus Health Tester

Operates with the Fluke 1750 Power Recorder It supplies accurate nonintrusive measurement of ac current The probe has a current range from 0.05 A to 40 A The frequency range is 40 Hz to 5 kHz The clamp is approved for CAT III 600 V

Operates with the Fluke 1750 Power Recorder It supplies accurate nonintrusive measurement of ac current The probe has a current range from 0.05 A to 40 A The frequency range is 40 Hz to 5 kHz The clamp is approved for CAT III 600 V

Insulation Test Range: 0.1MΩ to 2000MΩ Insulation Test Voltages: 500 V, 1000 V Saves both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio Repetitive or hard-to-reach testing is easy with the remote test probe Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection Auto-discharge of capacitive voltage for added user protection AC/DC voltage: 0.1 V to 600 V 200 mA Continuity Resistance: 0.01 Ω to 20.00 K Ω Save battery power with auto Power off Read measurements easily with large, backlit display CAT IV 600 V over-voltage category rating for added user protection

Category: Megohmmeters

Insulation Test Range: 0.1MΩ to 2000MΩ Insulation Test Voltages: 500 V, 1000 V Saves both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio Repetitive or hard-to-reach testing is easy with the remote test probe Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection Auto-discharge of capacitive voltage for added user protection AC/DC voltage: 0.1 V to 600 V 200 mA Continuity Resistance: 0.01 Ω to 20.00 K Ω Save battery power with auto Power off Read measurements easily with large, backlit display CAT IV 600 V over-voltage category rating for added user protection

Insulation Test Range: 0.01MΩ to 10GΩ Insulation Test Voltages: 50V, 100V, 250V, 500V, 1000V Automatic calculation of Polarization Index and Dielectric Absorption Ratio saves both time and money Compare (Pass/Fail) function makes repetitive tests simple and easy Saves both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio Repetitive or hard-to-reach testing is easy with the remote test probe Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection Auto-discharge of capacitive voltage for added user protection AC/DC voltage: 0.1 V to 600 V 200 mA Continuity Resistance: 0.01 Ω to 20.00 K Ω Save battery power with auto Power off Read measurements easily with large, backlit display CAT IV 600 V over-voltage category rating for added user protection

Category: Megohmmeters

Insulation Test Range: 0.01MΩ to 10GΩ Insulation Test Voltages: 50V, 100V, 250V, 500V, 1000V Automatic calculation of Polarization Index and Dielectric Absorption Ratio saves both time and money Compare (Pass/Fail) function makes repetitive tests simple and easy Saves both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio Repetitive or hard-to-reach testing is easy with the remote test probe Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection Auto-discharge of capacitive voltage for added user protection AC/DC voltage: 0.1 V to 600 V 200 mA Continuity Resistance: 0.01 Ω to 20.00 K Ω Save battery power with auto Power off Read measurements easily with large, backlit display CAT IV 600 V over-voltage category rating for added user protection

Test voltages to up 10 kV CAT III 1000 V, CAT IV 600 V safety rating Warning function alert for increased user safety Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V Up to 99 memory locations Over 750 tests between battery charges Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) Guard system eliminates the effect of surface leakage current on high-resistance measurements Large digital/analog LCD Capacitance and leakage current measurement Ramp function for breakdown testing Resistance measurements up to 2TΩ Timer settings up to 99 minutes