Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter

FEATURES ● Microprocessor-controlled.● Measures insulation (MΩ), Continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm (2.677” × 1.338” ) large LCD display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 200mA short circuit testing current for continuity.● Auto ranging.● Fuse protection.● Data hold function● BS 16 edition.     SPECIFICATIONS   Insulation Resistance     Test voltage 250V / 500V / 1000V Measuring ranges (Auto ranging) 0-2MΩ / 0-20MΩ / 0-200MΩ / 0-2000MΩ Output voltage open circuit +10% Accuracy 0-2MΩ : ±(5%rdg+5dgt) 0-20MΩ : ±(1.5%rdg+5dgt) 0-200MΩ : ±(2.5%rdg+3dgt) 0-2000MΩ : ±(5%rdg+5dgt) Resolution 0-2MΩ : 1kΩ 0-20MΩ : 10kΩ 0-200MΩ : 100kΩ 0-2000MΩ : 1MΩ Output current 1mA DC AC Voltage     Range 0-600V  Resolution 1V Line frequency range 40-120 Hz Accuracy ±(1.5%rdg+3dgt) Current for...

FEATURES ● Measures insulation (MΩ), Continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm (2.677” × 1.338” ) large LCD display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 210mA short circuit testing current for continuity.● External voltage warning indication.● Fuse protection.● BS 16 edition     SPECIFICATIONS   Insulation Resistance     Test voltage (DC V) 250V / 500V 1000V Measuring ranges 0-200MΩ  0-2000MΩ Resolution 1 count / 100kΩ 1 count / 1MΩ Accuracy ±(1.5%rdg+5dgt) ±(3%rdg+3dgt) (under 1GΩ/2000MΩ) ±(5%rdg+3dgt) (under 2GΩ/2000MΩ) Output voltage on open circuit Rated test Voltage +10% Output current 1mA DC Power consumption 250mA  Continuity     Measuring range 0-20Ω    0-2kΩ Accuracy ±(1.5%rdg+5dgt) ±(1.5%rdg+3dgt) Resolution 0.01Ω      1Ω Buzzer sound...

FEATURES ● Timer for test function (count 3-5 minutes).● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm (2.677” × 1.338”) large LCD display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 200mA short circuit testing current for continuity.● External voltage warning indication.● Fuse protection.● Data hold function● Auto power off function.● BS 16 edition.     SPECIFICATIONS   Insulation Resistance     Test voltage (DC V) 250V / 500V / 1000V Measuring ranges (Auto ranging) 0-20MΩ / 0-200MΩ / 0-2000MΩ Accuracy 0-20MΩ : ±(1.5%rdg+5dgt) 0-200MΩ : ±(2.5%rdg+3dgt) 0-2000MΩ : ±(5%rdg+5dgt) Output voltage on open circuit Rated test Voltage +10% Output current 1mA DC Power consumption 250mA  Continuity     Measuring range 0-20Ω / 0-200Ω / 0-2000Ω Accuracy ±(1.5%rdg+3dgt) Resolution 0.01Ω / 0.1Ω / 1Ω Buzzer sound below under 10Ω Open circuit terminal voltage 4V DC...

FEATURES ● Microprocessor-controlled.● 68 × 34mm(2.677” × 1.338”) large LCD display.● 3½ digital LCD(2000 counts) a LCD indicated instrument for    insulation.(MΩ), continuity(Ω) and AC voltage.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA DC load.● >200mA short circuit testing current for a resistance tests.● Auto ranging.● REL function.● Auto power OFF.● Fuse protection.● Auto data hold.● BS 16 edition.     SPECIFICATIONS   Insulation Resistance     Test voltage (DC V) 250V / 500V / 1000V Measuring ranges (Auto ranging) 0-2MΩ / 0-20MΩ / 0-200MΩ / 0-2000MΩ Output voltage on open circuit +10% Accuracy 0-2MΩ : ±(5%rdg+5dgt) 0-20MΩ : ±(1.5%rdg+5dgt) 0-200MΩ : ±(2.5%rdg+3dgt) 0-2000MΩ : ±(5%rdg+5dgt) Resolution 0-2MΩ : 1kΩ 0-20MΩ : 10kΩ 0-200MΩ : 100kΩ 0-2000MΩ : 1MΩ Output current 1mA DC AC Voltage     Range 0-600V Resolution 1V Line frequency...

FEATURES ● Microprocessor-controlled with advanced safety features.● Three test voltages : 250 / 500 / 1000V.● Displays and sound warning if external voltage present.● Ener-Save™ feature to extend battery life.● Continuous battery monitoring.● Auto ranging / auto-null / auto-off.● Insulation tested at 1mA.● Built-in carry case, test leads in separate pouch.● Real-time barg-raph display of test voltage and voltage decay during    discharge.● Audible and visual message displayed if external voltage is present.● Large LCD.● Display can be customized for special orders.● Continuity buzzer.● Show test time duration (up to 99.9s) for easy comparison.● BS 16 edition.     SPECIFICATIONS         Insulation Resistance     Test voltage (DC V) 250V     /     500V     /   1000V Measuring ranges (Auto ranging) 0-1000MΩ / 0-2000MΩ / 0-3000MΩ Accuracy ±3%rdg Output current 1mA DC min at 0.25MΩ(250V) 1mA DC min at 0.5MΩ(500V) 1mA DC min...

FEATURES ● High quality Taut Band movement.● Measures insulation(MΩ) and AC voltage.● LED indiction for testing insulation.● Highly efficiency and accurate DC-DC converter.● Battery check function.● Compact and lightweight.● AC voltage measurement can be made without depressing the test    button.     SPECIFICATIONS   Insulation Resistance     Test voltage (DC V) 100V Output voltage on open circuit Rated test voltage +10% Measuring ranges 0-200MΩ Mid-scale value 5MΩ Accuracy 0.2-100MΩ : ± 5% rdg 0.7% of scale length at other ranges Short circuit current 1mA DC AC Voltage     Range 0-500V Accuracy ± 2.5% of full scale General     Operating temperature & humidity 0°C ~ 40°C relative humidity up to 85% Storage temperature & humidity -10°C ~ 50°C relative humidity up to 85% Dimensions 175(L) × 85(W) × 75(D) mm Weight (battery included) Approx. 510g Power source 1.5V (AA) × 4 Safety standard EN...

FEATURES ● High quality Taut Band movement.● Battery operated.● Solid state circuitry.● Battery check feature.● Automatic circuit discharge.● Three insulation test voltages.● Color-coded scale.● AC voltage measurement.● Fuse protected.   SPECIFICATIONS   Insulation Resistance     Test voltage (DC V) 50V   /   125V   /   250V Measuring ranges 0-20MΩ / 0-50MΩ / 0-100MΩ Output voltage on open circuit Rated test voltage +10% Accuracy ±5% of indicated value Short circuit terminal current 2mA DC Power consumption 190mA Continuity     Measuring range 0-50Ω & ∞ Accuracy ± 5% of scale length Open circuit terminal voltage 445mV DC Approx. Short circuit terminal current 145mA DC Approx. Power consumption 200mA AC Voltage     Range 0-600V AC Accuracy ± 2.5% of full scale Line frequency range 40-1kHz General     Dimensions 170(L) × 165(W) × 92(D) mm Weight ...

FEATURES ● High contrast OLED display● Designed for viewing in the dark, for mining industry.● Wide viewing angle.● Smart microprocessor-controlled.● 2 x 16 characters, large, High Contrast, Intelligent OLED Display.● Automatically calculates Delectric Absorbtion Ration (DAR).● Automatically calculates Polarization Index (PI).● Insulation resistance; Auto-ranging on all ranges.● Ener-Save● Bar graph indicates test voltage. Rise and decay can be obeserved.● External voltage presence warning (>500Vac or Vdc)● Overload protection● Low battery indicator (real time battery voltage mearsurement)● Measures insulation time duration of the test● Better than 10% accuracy on all ranges● Auto-off   SPECIFICATIONS   Test voltage From 500Vdc to 10kVdc Adjustable in 500V Steps Preset buttons 1kV, 2.5kV, 5kV, 10kV Measuring range 800kΩ-500GΩ (auto-ranging) Accuracy ±5% ± 2 digits Output power limit 1W Voltage regulation Selected Voltage +20%-5% of nominal value unless current limited. Meaning that if output current is too high, the voltage will...

503 Service Unavailable

Service Unavailable

The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

Additionally, a 503 Service Unavailable error was encountered while trying to use an ErrorDocument to handle the request.